Skip to main content

Moisture Testing by Oven Method


DEFINATION: This method determines the moisture and any other material volatile under the conditions of the test.

SCOPE:  Applicable to food products like cereal & cereal products, fruits & vegetable products, beverages, milk & milk products etc.
APPARATUS:
1. Moisture dish: Made of aluminium sheet about 0.45 to 0.56 mm thickness, 70-80 mm in diameter and 20 mm deep provided with tight fitting slip-over cover.

2. Desiccator: Containing an efficient desiccant, such as phosphorus pentoxide or self indicating Silica Gel.

3. Hot Air Oven: Preferably electrically heated, with temperature controlled device.

PREPARATION OF SAMPLE:

Grind & mix the sample thoroughly when using for moisture determination.
Always store the sample in a closed container or pack.

PROCEDURE:

1.       Weigh accurately around 5 g sample into a moisture dish, which has been dried previously in oven, cooled in the dessicator and weighed. 
2.       Place the dish in the hot air oven for the 2 hours at specified temp. (130°C for flour and 105°C for processed foods). 
3.       Remove the dish from the oven, close the lid.
4.       Cool in the dessicator containing desiccant and weigh. 
5.       Repeat this procedure, but keep the dish in the oven for additional time as mentioned in the table below. Or for an hour each time until the difference between the two successive weighing does not exceed one milligram.

CALCULATION:


Moisture and Volatile matter              w x 100
          Content, % by weight =              -----------
      W
Where,
w  = loss in weight in grams of the material on drying, and
                W = weight in grams of the material taken for the test.


Method Ref:
·        info@executivejhansi.com

Comments

Popular posts from this blog

Food Safety management - 2020

FOOD PRODUCT SAFETY PLAN & FACTORY IMPROVEMENT GUIDELINE CONTENTS 1. SENIOR MANAGEMENT COMMITMENT 1.1 SENIOR MANAGEMENT COMMITMENT AND CONTINUAL IMPROVEMENT 1.2 ORGANISATIONAL STRUCTURE, RESPONSIBILITIES AND MANAGEMENT AUTHORITY                                                              2. THE FOOD SAFETY PLAN – HACCP 2.1 THE HACCP FOOD SAFETY TEAM (EQUIVALENT TO CODEX ALIMENTARIUS STEP 1 ) 2.2 PREREQUISITE PROGRAMMES 2.3 DESCRIBE THE PRODUCT (EQUIVALENT TO CODEX ALIMENTARIUS STEP 2 ) 2.4 IDENTIFY INTENDED USE (EQUIVALENT TO CODEX ALIMENTARIUS STEP 3 ) 2.5 CONSTRUCT A PROCESS FLOW DIAGRAM (EQUIVALENT TO CODEX ALIMENTARIUS STEP 4 ) 2....

Protein Content & nitrogen content Analysis in food product

How to  analysis nitrogen content & protein analysis in food product                                         Kjeldhal Method The method is applicable for determination of nitrogen content and hence proteins present in the sample.   The method is based on digestion of test sample in sulphuric acid during which organic compounds are oxidized to carbon dioxide and water and nitrogen of amino groups of protein is converted to ammonium sulphate.   Further, in the presence of sodium hydroxide, ammonium sulphate is broken down to form ammonia, which is distilled along with steam into a conical flask containing acid.   The amount of ammonia is determined by titration. qe@executivejhansi.com APPARATUS 1.        Micro kjeldhal assembly (Parnas-Wagner Assembly) 2.        Kjeldhal flask of volum...

Food safety management systems ISO22000

ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see...

TEST PROCEDURE FOR CRUDE FIBRE ESTIMATION

            HOW TO FIND CRUDE FIBRE IN FOOD PRODUCT REAGENTS 1.        Dilute sulphuric acid            - 1.25 % m/v, accurately prepared 2.        Sodium hydroxide solution - 1.25 % m/v. accurately prepared APPARATUS 1.        Electric air Oven 2.        Thimble 3.        Soxhlet apparatus 4.        Reflux condenser 5.        Gooch crucible 6.        Muffle furnace PROCEDURE 1.        Dry to constant mass about 5 g of the material in an electric air oven at 105 to 110 deg C.   Weigh accurately about 2.5 g of the dried material into a thimble and extract for about one hour with petroleum ethe...

HACCP Principal

Application of the Principles of HACCP Principle 1 - Conduct a Hazard Analysis Principle 2 - Identify the Critical Control Points Principle 3 - Establish Critical Limits Principle 4- Monitor CCP Principle 5 - Establish Corrective Action Principle 6 - Verification Principle 7 - Recordkeeping Principle 1 - Conduct a Hazard Analysis The application of this principle involves listing the steps in the process and identifying where significant hazards are likely to Occur. The HACCP team will focus on hazards that can be prevented, eliminated or controlled by the HACCP plan. A justification for including or excluding the hazard is reported and possible control measures are identified. Principle 2 - Identify the Critical Control Points A critical control point (CCP) is a point, step or procedure at which control can be applied and a food safety hazard can be prevented, eliminated or reduced to acceptable levels. The HACCP team will use a CCP decision ...

DETERMINATION OF FAT CONTENT

                                DETERMINATION OF FAT CONTENT SCOPE : All raw materials and finished products SAMPLE PREPARATION 1.       Mix thoroughly the sample & place it in a mixer grinder.   2.       Operate the grinder for 10 seconds.   3.       With the help of scoop mix well the content and operate further for five seconds.   4.       Mix thoroughly and make it uniform mass on a butter paper. APPARATUS     1.       Soxhlet extraction apparatus. 2.       Air - oven. (0 - 105 ° C). 3.       Glass - flat bottom flask - 250 ml 4.       Whatman Cellulose Extraction thimbles 25 mm x 80 mm. 5.       Desiccator 6. ...